When a buyer asks whether your cluster is InfiniBand-ready, they are not asking whether you own InfiniBand switches. They are asking whether the fabric will let a multi-node training job run at close to the speed the GPUs allow.
This post explains what that question really covers, what to document so you can answer it in writing, and how to test your own fabric before a buyer does.
- InfiniBand-ready means one fast network adapter per GPU, a non-blocking topology and measured collective performance, not just the presence of InfiniBand
- NDR runs at 400 Gb/s per port and an eight-GPU node with eight adapters has 3.2 Tb/s of fabric bandwidth
- Moving 280 GB of gradients takes under a second at 300 GB/s and about 22 seconds at 12.5 GB/s, which is why the fabric decides training speed
- Oversubscription, shared uplinks and mixed generations are the usual reasons a nominally fast cluster underperforms
- Document adapter model and count, switch generation, topology, oversubscription ratio and test results
- Run NCCL collective tests yourself and share the numbers before a buyer asks
What the question really covers
Multi-node training splits one job across many GPUs, and after every step those GPUs must exchange gradients. The speed of that exchange sets how much of the time the GPUs spend computing and how much they spend waiting. A buyer paying for a hundred GPUs wants to know how much of that hundred they will actually be using.
So the question breaks into five parts. How fast is each network adapter, and is there one per GPU? What switches connect them, and of what generation? How are the switches arranged, and is the fabric oversubscribed? What do collective-communication tests actually show? And how large a cluster can sit on one fabric without crossing a slower boundary? The comparison with Ethernet is covered in InfiniBand vs Ethernet.
The generations
| Generation | Speed per port | Typical pairing |
|---|---|---|
| HDR | 200 Gb/s | Older A100-era clusters |
| NDR | 400 Gb/s | H100, H200 and many B200 systems |
| XDR | 800 Gb/s | Newer Blackwell Ultra platforms |
A buyer will want the generation stated, and will notice if a current-generation GPU is paired with an older fabric. An H200 or B200 node connected at HDR speeds will bottleneck on communication long before it runs out of compute.
One adapter per GPU
A standard eight-GPU HGX node is built with one 400 Gb/s adapter for each GPU, which gives 3.2 Tb/s, or about 400 GB/s, of fabric bandwidth leaving the node. That ratio matters. A node with only two adapters shared among eight GPUs has a quarter of the bandwidth, and the GPUs queue behind each other every time they synchronise.
The arithmetic shows why buyers press on this. Suppose a training step has to move about 280 GB of gradient traffic between nodes. At 300 GB/s effective bandwidth that takes just under a second. At 12.5 GB/s, roughly a 100 Gb/s Ethernet link, it takes about 22 seconds. This is deliberately simplified, since real systems overlap communication with compute, but it shows the order of magnitude and why the fabric decides how fast training runs.
Topology and oversubscription
The switches and how they are wired matter as much as the adapters. A non-blocking fat-tree gives every node full bandwidth to every other node at the same time. An oversubscribed fabric, where the uplinks from each leaf switch carry less bandwidth than the nodes attached below it, works fine until many nodes communicate together, which is exactly what a large training job does.
State the oversubscription ratio plainly. One to one means non-blocking. Two to one means that under full load each node gets half its nominal bandwidth. A provider who says InfiniBand without giving the ratio leaves the buyer to assume the worst, and a buyer running a serious job will insist on knowing.
Rail-optimised layouts, where each GPU's adapter connects to its own dedicated switch plane, keep traffic between corresponding GPUs on different nodes to a single hop. Describing whether your cluster is rail-optimised, and across how many planes, is the kind of detail that separates a purpose-built fabric from an adapted one.
What to document
Prepare a one-page fabric sheet for each cluster. It should list the adapter model and count per node, the link speed, the switch model and generation, the topology and the oversubscription ratio, the cable and optics types, and the maximum number of nodes on a single non-blocking fabric. Add whether in-network collective acceleration is available and whether the fabric is shared with any other tenant.
Note the other networks too. Storage traffic should not share the training fabric, and a separate storage network and a management network belong on the sheet. A buyer reading it should be able to answer their own architecture questions without a call.
Test before they do
The standard test is NCCL's collective benchmarks, particularly all-reduce across the nodes you plan to offer. They report achieved bus bandwidth, which can be compared with the theoretical figure for the adapters. A healthy fabric lands close to it, and a shortfall usually points to a misconfigured link, a degraded cable, an oversubscribed uplink or a mixed-generation switch.
Run the test at several scales: two nodes, eight, and the full cluster. Performance that holds at two nodes and drops at sixteen tells you where the topology starts to bite. Share the results with the fabric sheet. A provider who can hand over measured numbers answers the question before it is asked.
Ethernet and RoCE, honestly
Not every provider runs InfiniBand, and the answer is not always no. A well-engineered RDMA-over-Ethernet fabric with proper congestion control can perform well, and some of the largest clusters in the world use it. The condition is the same: one fast adapter per GPU, a non-blocking design and measured results.
Where an operator offers Ethernet, say so, describe it accurately and show the tests. The baseline requirement for listing is InfiniBand or high-bandwidth inter-node networking, and a precise description of what you have serves better than an optimistic label. Single-node inference does not need any of this, which is worth saying too.
Common mistakes
Calling a cluster InfiniBand-ready because the nodes have InfiniBand ports, without confirming the switches and topology. Mixing adapter generations within one job. Letting storage traffic share the training fabric. Quoting a cluster size larger than the non-blocking portion of the fabric. And describing the fabric in marketing language rather than numbers.
Each of those is cheap to avoid and expensive to discover during a buyer's acceptance test. Interconnect tier is also one of the things that moves where a quote lands, because capacity on InfiniBand sits above Ethernet at the same GPU count, which is covered in the October benchmark.
How to put it on the form
The provider application has a free-text box for exactly this. A paragraph such as: eight H200 nodes, one 400 Gb/s adapter per GPU, NDR InfiniBand, non-blocking fat-tree at one to one, rail-optimised, NCCL all-reduce results attached, separate storage and management networks. A reviewer can match that straight to a request, and the walkthrough is in the provider form, explained.
List your capacity and start getting quoted.
One node is enough to start. There is no cost to apply or list.
Apply as a providerFrequently asked questions
What does InfiniBand-ready mean?
One fast adapter per GPU, a current-generation fabric, a non-blocking topology and measured collective performance. Having InfiniBand ports on the nodes is not enough.
What bandwidth does an eight-GPU node need?
A standard HGX node has one 400 Gb/s adapter per GPU, giving 3.2 Tb/s or about 400 GB/s leaving the node. Fewer adapters shared across GPUs cut that proportionally.
What is oversubscription and why does it matter?
It is when switch uplinks carry less bandwidth than the nodes attached below them. It is invisible under light load and cuts per-node bandwidth when many nodes communicate together, as large training jobs do.
How do I prove my fabric performs?
Run NCCL all-reduce tests at several scales, compare achieved bus bandwidth with the theoretical figure, and share the results alongside a one-page fabric sheet.
Can Ethernet be acceptable instead of InfiniBand?
Yes, if it is a properly engineered RDMA fabric with one fast adapter per GPU, a non-blocking design and measured results. Describe it accurately rather than labelling it InfiniBand.
Last reviewed: 4 November 2026. Link speeds and generations from NVIDIA's published InfiniBand and HGX specifications. The gradient-transfer arithmetic is a simplified illustration that ignores overlap between communication and compute. Baseline listing requirements from the GPUaaS.com provider application page. Apply to list GPU capacity on GPUaaS.com.